Equipment can be installed indoors or outdoors without special requirements up to 300 m (984 ft) away from the coast.
-
Precautions need to be taken if equipment is installed within 50 to 300 m (164 to 984 ft) from the coast.
-
Recommended Installation: Indoor installation should be prioritized, relying on enclosed or semi-enclosed spaces.
-
Semi-Enclosed Exception: If the space directly faces the ocean, effective barrier structures must be installed between the equipment and the sea to block marine airflow.
-
Outdoor Installation: This is only permitted when indoor installation is not possible. The following protective measures must be implemented:
-
A physical protective structure must be constructed to shield the equipment from sea breezes. The machine must be placed between 40 and 100 cm (15.7 and 39.4") away from the structure.
-
The top of the equipment must be covered to avoid vertical ocean airflow.
-
-
-
Installation is prohibited within 50 m (164 ft) of the coast due to high salt fog concentration, intense corrosion, and climate conditions, which violate operational safety standards.
Note:
Any operational environment must be properly ventilated to dissipate heat. Installation must strictly adhere to the technical parameters for spatial clearance, outlined in the product manual. Maintain a minimum safe distance from surrounding obstructions to improve heat dissipation and prolong equipment life.