You can use a generator and F3800 Plus in the following scenarios:
1. With 240V Generators
- F3800 Plus Only
The generator connects to F3800 Plus's Home Power Panel port. Use the F3800 Plus's L14-30R AC output port to deliver up to 6,000W (240V) or the TT-30R port for up to 3,000W (120V).
- F3800 Plus + Transfer Switch/Inlet Box
The generator connects to F3800 Plus's Home Power Panel port. Use the F3800 Plus's L14-30R AC output port to deliver up to 6,000W (240V).
- F3800 Plus + Home Power Panel
Connect the generator to one of the Home Power Panel's power station ports for up to 6,000W (240V) of generator power.
2. With 120V Generators
- F3800 Plus Only
Connect the generator to F3800 Plus's Home Power Panel port. Use the F3800 Plus's TT-30R AC output port to provide up to 3,000W (120V) max. This setup is an alternative to grid power. Note that the generator must output 120V pure sine wave power with a total harmonic distortion (THD) of less than 5%.
- F3800 Plus + Transfer Switch/Inlet Box
The generator connects to F3800 Plus's Home Power Panel port. Use the F3800 Plus's TT-30R AC output port to deliver up to 3,000W (120V).
If you have any questions, feel free to contact us for further assistance.